Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Sci Rep ; 12(1): 13491, 2022 08 05.
Article in English | MEDLINE | ID: covidwho-2050506

ABSTRACT

Knowledge of the factors affecting the difference in kinetics and longevity of the neutralizing antibody (nAb) response to SARS-CoV-2 is necessary to properly prioritize vaccination. In the present study, from March to December 2020, of the 143 patients who recovered from COVID-19, 87 underwent study visits scheduled every 3 months. Patient demographics and blood samples were collected followed by a plaque reduction neutralization test to analyze nAb titers. A linear mixed model was used to compare the effects of sex, age, and disease severity over time. Results demonstrated a gradual reduction in nAb titers over time with a significant decrease from 6 to 9 months post-COVID-19 infection (p < 0.001). In time-to-sex, age, and disease severity comparisons, reduction in nAb titers over time was unaffected by sex (p = 0.167), age (p = 0.188), or disease severity (p = 0.081). Additionally, the nAb titer was 1.46 times significantly higher in those aged ≥ 50 years than in those aged < 50 years (p = 0.036) irrespective of time Moreover, the nAb titer was 2.41 times higher in the moderate or above than that in the below moderate disease severity group (p < 0.001). However, no significant differences were observed in terms of sex (p = 0.300). Given the reduction in nAbs over time, maintaining protective neutralizing antibodies regardless of sex, age, or disease severity is needed.


Subject(s)
Antibodies, Neutralizing , COVID-19 , Antibodies, Viral , Humans , SARS-CoV-2 , Severity of Illness Index
2.
Clin Lab ; 68(9)2022 Sep 01.
Article in English | MEDLINE | ID: covidwho-2025359

ABSTRACT

BACKGROUND: To assess protective immunity among a general population against severe acute respiratory syndrome coronavirus 2, the correlation of the commercially available solid-phase assay (SPA) for SARS-CoV-2 IgG with a neutralization assay must be investigated. METHODS: Both the neutralization assay and SPA were performed on samples of 143 recovered coronavirus disease 2019 (COVID-19) patients. SARS-CoV-2 IgG was measured using two SPAs for the chemiluminescence immunoassay principle with different target proteins: nucleocapsid and spike protein (Architect i2000SR [Abbott] and Liaison XL [DiaSorin], respectively). The plaque reduction neutralization test (PRNT) was conducted to obtain titers for the neutralizing antibody. RESULTS: All patients had PRNT titers ranging from 10 to 2,560. Spike Ab SPA had greater sensitivity than nucleocapsid Ab SPA (81.1% [116/143] and 70.6% [101/143], respectively, p = 0.003). The values measured for both SPAs had a positive correlation with the PRNT titers (both R = 0.77, p < 0.001). To predict a high PRNT titer (≥ 160), cutoff values of two SPAs were adjusted based on receiver-operating characteristics curve analysis. The nucleocapsid Ab SPA (cutoff index of 4.17) attained 90.3% sensitivity and 75.9% specificity, whereas the spike Ab SPA (cutoff value of 109 unit/mL) attained 87.1% sensitivity and 89.3% specificity. Therefore, the spike Ab SPA had greater specificity than the nucleocapsid Ab SPA (p = 0.003). CONCLUSIONS: The qualitative SPA for nucleocapsid Ab, as well as the quantitative SPA for spike Ab, had a modest positive correlation with the neutralization assay. However, spike Ab SPA was more suitable for neutralizing capacity.


Subject(s)
Antibodies, Neutralizing , COVID-19 , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoglobulin G , SARS-CoV-2 , Spike Glycoprotein, Coronavirus
3.
Viruses ; 13(9)2021 09 14.
Article in English | MEDLINE | ID: covidwho-1411074

ABSTRACT

Presently, the use of convalescent plasma and hyperimmunoglobulin obtained from individuals who have recovered from coronavirus disease 2019 (COVID-19) has proved to potentially provide passive antibody-based immunity, thereby leading to several clinical trials to develop an immune-based COVID-19 treatment. However, the therapeutic efficacy of hyperimmunoglobulin in critically ill patients with COVID-19 remains unknown. On 23 October 2020, we first administered GC5131 in a compassionate-use program to critically ill patients at the Kyungpook National University, Chilgok Hospital, Korea. Since then, five more critically ill patients were treated with GC5131 in this compassionate-use program in our hospital up until 17 December 2020. We retrospectively reviewed the clinical responses of six critically ill patients diagnosed with COVID-19 who received the hyperimmunoglobulin concentrate, GC5131, which was produced by the Green Cross Corporation. After the administration of GC5131, five patients died due to an exacerbation of COVID-19 pneumonia. GC5131 was ineffective when administered to critically ill patients with COVID-19. Nevertheless, we propose that to expect a therapeutic effect from GC5131, it should be administered as early as possible to avoid the excessive inflammatory response phase in patients with severe and advanced COVID-19 infection. This step was difficult to achieve in the real world due to the time required for decision making and the process of the compassionate-use program.


Subject(s)
COVID-19 Drug Treatment , COVID-19/therapy , COVID-19/virology , Critical Illness , Immunoglobulins/therapeutic use , SARS-CoV-2/drug effects , Aged , COVID-19/diagnosis , Compassionate Use Trials , Female , Humans , Immunization, Passive , Male , Republic of Korea , Treatment Outcome , COVID-19 Serotherapy
SELECTION OF CITATIONS
SEARCH DETAIL